Design | Thermosiphon with the lopastny water pump. Thermostatic adjustment. With a separate broad tank. The fan with the vyazkostny coupling. The additional electric fan joins and switched off by a thermoswitch |
Cooling liquid
| mix of soft water (60 %) and antifrizny concentrate (40 %) |
Antifrizny concentrate
| G12 (red color) (do not mix with any other) |
System volume
|
L engines 1.6, 1.8 | 5.0 l |
Concentration of antifreeze in cooling liquid for ensuring frost resistance to
|
– 35°С | 50 % |
– 25°С | 40 % |
Thermostat
|
Temperature of the beginning of opening | 87°С |
Temperature of complete opening | 102°С |
Valve stroke | not less than 7 mm |
Fan thermoswitch | |
Inclusion/switching off of the 1st step | 92-97/84-91°C |
Inclusion/switching off of the 2nd step | 99-105/91-98°C |
Stopper of a broad tank
|
The valve of superfluous pressure opens | 1.4–1.6 bar |
The valve of depression opens | 0.06–0.1 bar |
Conditioner coolant
|
Type | R134a |
Volume, гр. | 750 ± 50 |
Refrigerator oil
|
G052 type | 154 A2 |
Volume, cmi | 135 ± 15 |
Efforts of a tightening of carving connections
|
The moments of an inhaling of fixture are given also in the text of Head and on some иллюстрациях*.
*vydelenny in the text a bold print the moments of an inhaling are subject to exact observance; the efforts not allocated with a bold print are given only roughly The water pump on the engine
|
Engines | 15 H of m |
Thermostat cover | 15 H of m |
Conditioner compressor | 45 H of m |