Audi A3

since 1997 of release

Repair and car operation



Audi A3
+ Maintenance instruction
+ Current leaving and service
+ Engine
+ Systems of cooling, heating
+ the Power supply system and production of the fulfilled gases
- Engine electric equipment
   + System of electronic control by ignition and injection
   - Charge and start systems
      Storage battery
      Removal and installation of the storage battery
      Check of the storage battery
      The generator - general information and security measures
      Check of the established generator
      Removal and generator installation
      Check and replacement of brushes of the generator and tension regulator
      Starter - general information
      Check of system of start of the engine
      Removal and starter installation
      Check, removal and installation of the traction relay of a starter
+ Manual box of gear shifting
+ Automatic transmission and models with a full drive
+ Coupling and power shafts
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment
+ Elektroskhema


38a8de3e

Check of the established generator

GENERAL INFORMATION

At normal movement the lamp of control of a charge should go out. Otherwise, malfunction consists in the generator or a tension regulator. First, check electric connections of the generator. Check, whether correctly will pull a driving belt. Further check can be carried out only on the removed generator, however previously it is necessary to check all safety locks.

Check of a regulator of tension

PERFORMANCE ORDER
1. Turn on the voltmeter between positive and negative poles of the storage battery.
2. Start the engine. At start tension can decrease to 8 In (at external temperature +20°С).
3. Lift number of turns of the engine to 3000 rpm. Thus tension should make from 13.5 to 14.5 V.Eto specifies that the generator and a regulator are efficient. Tension of the generator (onboard tension) should be higher than tension of the storage battery that the battery in the course of movement was charged.
4. Check stability of work of a regulator of tension. For this purpose include a driving beam and repeat measurements at 3 000 rpm. The measured tension should not be more than 0.4 In earlier measured values.
5. If tension does not correspond to demanded sizes, worn-out brushes of the generator, weak springs of brushes, a faulty regulator of tension, the faulty diode, break of a winding of a stator or defective contact rings of a rotor can be a cause of defect.