Number of the diagnostic channel |
Display
|
1 | System refusal – is highlighted a malfunction code (interpretation of codes is presented below) |
2 | The indication of the sensor of temperature under a ceiling upholstery of salon (G86) |
3 | The indication of the sensor of temperature around an instrument guard (G56) |
4 | The indication of the sensor of temperature in an air inlet (G89) |
5 | Indication of the forward sensor of temperature of external air (G17) |
6 | Indication of the sensor of temperature of external air |
7 | The indication of the sensor of temperature of external air (G109) forced in salon |
8 | Value of temperature around the sensor of position of the electromotor of a drive of an adjusting zaslonka (G92) |
9 | Value of temperature around an adjusting zaslonka |
10 | Defined, not changeable size of temperature around an adjusting zaslonka |
11 | Indication of the sensor of position of the electromotor of the central adjusting zaslonka (G112) |
12 | Demanded value of provision of the central zaslonka |
13 | The indication of the sensor of position of the electromotor of a drive of a zaslonka of switching of the direction of supply of air (having blown wind glass/supply of air in foot wells) (G114) |
14 | Demanded value of provision of a zaslonka of switching of the direction of distribution of air |
15 | Indication of the sensor of position of the electromotor of a drive of an air zaslonka (G113) |
16 | Demanded value of provision of an air zaslonka |
17 | Speed of movement of the car (km/h) |
18 | The valid supply voltage of the fan of a heater (In) |
19 | The valid supply voltage of the fan of a heater (In) |
20 | Supply voltage To/in (In) |
21 | Number of power failures (without short-term jumps) |
22 | Cyclically overestimated indication of the sensor switch of pressure of a coolant In (F118) |
23 | Cycles of the overestimated indications of the sensor switch of pressure of a coolant In (F118) |
24 | Cycling of sensors switches (without fluctuations) |
25 | Analog/digital form of indications of the sensor switch of activation of the kickdown mode |
26 | Analog/digital form of the indication of a control lamp of temperature of cooling liquid |
27 | The coded value |
28 | Turns of the engine (mines-1) |
29 | To/in compressor turns (rpm x 1.28) |
30 | Software version |
31 | Display check (all segments should be highlighted) |
32 | Counter of failures of the sensor of provision of a mixing zaslonka |
33 | Counter of failures of the sensor of provision of the central zaslonka |
34 | Counter of failures of the sensor of provision of a zaslonka of switching of the direction of distribution of air |
35 | Counter of failures of the sensor of provision of an air zaslonka |
36 | Value cold останова sensor of provision of a mixing zaslonka (G92) |
37 | Value hot останова sensor of provision of a mixing zaslonka (G92) |
38 | Value cold останова sensor of provision of the central zaslonka (G112) |
39 | Value hot останова sensor of provision of the central zaslonka (G112) |
40 | Value cold останова sensor of provision of a zaslonka of switching of the direction of distribution of air (G114) |
41 | Value hot останова sensor of provision of a zaslonka of switching of the direction of distribution of air (G114) |
42 | Value cold останова sensor of provision of a perepuskny zaslonka (G113) |
43 | Value hot останова sensor of provision of a perepuskny zaslonka (G113) |
44 | Counter of cycles of operation of the car |
45 | The calculated temperature in car salon (in figures) |
46 | The calculated temperature of external air (filtered) |
47 | Temperature of external air (not filtered, °C) |
48 | Temperature of external air (not filtered, in figures) |
49 | Counter of refusals of a speedometer/VSS |
50 | Parking time (in H · m нутах) |
51 | Temperature of cooling liquid of the engine, °C |
52 | The graphic channel 1 – address to interpretations of codes of malfunctions below
ATTENTION
At a channel 52 choice, on the display the following picture at first is highlighted: “__ _”. Electric target signals To/in are identified on fire of certain signals on the display.
|
53 | The graphic channel 2 – address to interpretations of codes of malfunctions below
ATTENTION
At a channel 53 choice, on the display the following picture at first is highlighted: “__ _”. Electric target signals To/in are identified on fire of certain signals on the display.
|
54 | Control parameters |
55 | Temperature of external air in °C or °F depending on a choice of a head of management To/in |
56 | Indications of the sensor of temperature under a ceiling upholstery, °C (G86) |
57 | Indications of the sensor of temperature under an instrument guard, °C (G56) |
58 | Indications of the sensor of temperature in an air inlet, °C (G89) |
59 | Indications of the forward sensor of temperature of external air, °C (G17) |
60 | Indications of the sensor of temperature of the fan of a heater, °C (G109) |
61 | Software version (last) |
Code of malfunction (DTC) |
Possible cause of failure
|
02.1 | Break in a chain of the sensor of temperature under a ceiling upholstery of G86; value by default at failure of the sensor: 128 |
02.2 | Short H · m ykany in a chain of the sensor of temperature under a ceiling upholstery of G86; Ю DTC 02.1 |
02.3 | Unstable violation of contact in a chain of the sensor of temperature under a ceiling upholstery of G86 |
02.4 | Unstable short H · m ykany in a chain of the sensor of temperature under a ceiling upholstery of G86 |
03.1 | Break in a chain of the sensor of temperature under an instrument guard of G56; Ю DTC 02.1 |
03.2 | Short H · m ykany in a chain of the sensor of temperature under an instrument guard of G56; Ю DTC 02.1 |
03.3 | Unstable violation of contact in a chain of the sensor of temperature under an instrument guard of G56 |
03.4 | Unstable short H · m ykany in a chain of the sensor of temperature under an instrument guard of G56 |
04.1 | Break in a chain of the sensor of temperature in G89 air inlet; at failure of the sensor the DTC 04.1 G17 Yu sensor signal is used |
04.2 | Short H · m ykany in a chain of the sensor of temperature in G89 air inlet; Ю DTC 04.1 |
04.3 | Unstable violation of contact in a chain of the sensor of temperature in G89 air inlet |
04.4 | Unstable short H · m ykany in a chain of the sensor of temperature in G89 air inlet |
05.1 | Break in a chain of the sensor of temperature of external G17 air; at failure of the sensor the DTC 04.1 G89 Yu sensor signal is used |
05.2 | Short H · m ykany in a chain of the sensor of temperature of external G17 air; Ю DTC 05.1 |
05.3 | Unstable violation of contact in a chain of the sensor of temperature of external G17 air; Value by default at failure of both sensors (G89 and G17): 128 |
05.4 | Unstable short H · m ykany in a chain of the sensor of temperature of external G17 air |
06.1 | Break in a chain of the sensor of temperature of cooling liquid of the engine (In) G110; If the sensor is faulty or is not established, the temperature of cooling liquid is calculated; diagnostics is possible only at temperature above 0°С (32°F) |
06.2 | Short H · m ykany in a chain of the sensor of temperature of cooling liquid of the engine (In) G110; Ю DTC 06.1 |
06.3 | Unstable violation of contact in a chain of the sensor of temperature of cooling liquid of the engine (In) G110 |
06.4 | Unstable short H · m ykany in a chain of the sensor of temperature of cooling liquid of the engine (In) G110 |
07.1 | Break in a chain of the sensor of temperature of the fan of a heater of G109; the Programmed correct value = 0 |
07.2 | Short H · m ykany in a chain of the sensor of temperature of the fan of a heater of G109; Ю DTC 07.1 |
07.3 | Unstable violation of contact in a chain of the sensor of temperature of the fan of a heater of G109 |
07.4 | Unstable short H · m ykany in a chain of the sensor of temperature of the fan of a heater of G109 |
08.1 | Break in a chain of the sensor of provision of a mixing zaslonka of G92; Automatic control of functioning of the driving electromotor becomes impossible, manual adjustment is required |
08.2 | Short H · m ykany in a chain of the sensor of provision of a mixing zaslonka of G92; Ю DTC 08.1 |
08.3 | Unstable violation of contact in a chain of the sensor of provision of a mixing zaslonka of G92 |
08.4 | Unstable short H · m ykany in a chain of the sensor of provision of a mixing zaslonka of G92 |
08.5 | Blocking of the sensor of provision of a mixing zaslonka of G92; the electromotor зациклен, the software aspires to eliminate the blocking reason |
08.6 | Failure of the sensor of provision of a mixing zaslonka of G92 |
08.7 | Unstable blocking of the sensor of provision of a mixing zaslonka of G92 |
11.1 | Break in a chain of the sensor of provision of the central zaslonka of G112; Automatic control of functioning of the driving electromotor becomes impossible, manual adjustment is required |
11.2 | Short H · m ykany in a chain of the sensor of provision of the central zaslonka of G112; Ю DTC 11.1 |
11.3 | Unstable violation of contact in a chain of the sensor of provision of the central zaslonka of G112 |
11.4 | Unstable short H · m ykany in a chain of the sensor of provision of the central zaslonka of G112 |
11.5 | Blocking of the sensor of provision of the central zaslonka of G112; the electromotor зациклен, the software aspires to eliminate the blocking reason |
11.6 | Failure of the sensor of provision of the central zaslonka of G112 |
11.7 | Unstable blocking of the sensor of provision of the central zaslonka of G112 |
13.1 | Break in a chain of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air; Automatic control of functioning of the driving electromotor becomes impossible, manual adjustment is required |
13.2 | Short H · m ykany in a chain of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air; DTC 13.1 |
13.3 | Unstable violation of contact in a chain of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air |
13.4 | Unstable short H · m ykany in a chain of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air |
13.5 | Blocking of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air; the electromotor зациклен, the software aspires to eliminate the blocking reason |
13.6 | Failure of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air |
13.7 | Unstable blocking of the sensor of provision of a zaslonka of switching of the direction of distribution of G114 air |
15.1 | Break in a chain of the sensor of provision of a perepuskny zaslonka of G113; At failure of the sensor the software exposes emergency value |
15.2 | Short H · m ykany in a chain of the sensor of provision of a perepuskny zaslonka of G113; Ю DTC 15.1 |
15.3 | Unstable violation of contact in a chain of the sensor of provision of a perepuskny zaslonka of G113 |
15.4 | Unstable short H · m ykany in a chain of the sensor of provision of a perepuskny zaslonka of G113 |
15.5 | Blocking of the sensor of provision of a perepuskny zaslonka of G113; the electromotor зациклен, the software aspires to eliminate the blocking reason |
15.6 | Failure of the sensor of provision of a perpuskny zaslonka of G113 |
15.7 | Unstable blocking of the sensor of provision of a perepuskny zaslonka of G113 |
17.0 | Failure of the sensor of speed of the VSS car |
18.1 | Constant wrong supply voltage of the fan of fresh air |
18.3 | Periodically wrong supply voltage of the fan of fresh air |
20.1 | Constant wrong supply voltage of the To/in compressor; the Compressor turns on only if tension of its food is supported at level not below 10.8В within not less than 25 seconds |
20.3 | Periodically wrong supply voltage of the To/in compressor; the Compressor turns on only |
22.1 | Break in a chain of the sensor switch of an elevated pressure of a coolant In F118; the Compressor remains switched off until the sensor switch will open |
22.3 | Unstable violation of contact in a chain of the sensor switch of an elevated pressure of a coolant In F118 |
22.5 | Break 120Х in a chain of the sensor switch of an elevated pressure of a coolant In F118; chain of a reaktivatsiya of the compressor, VAG 1551 scanner functioning |
29.1 | Constant soft proskalzyvaniye of a belt |
29.2 | Constant rigid proskalzyvaniye of a belt |
29.3 | Periodic soft proskalzyvaniye of a belt |
29.4 | Periodic rigid proskalzyvaniye of a belt |